Electrical installation
Wiring
Operation with another supplier
4
57
EDKCSEK002 DE/EN/FR 2.0
4.4.2
Operation with another supplier
Stop!
ƒ
After mains connection, wait at least one second before bridging
the charging current limitation (X26 = HIGH).
ƒ
Only release the controller (X6/SI1 = HIGH) if the charging
current limitation is bridged.
t [s]
HIGH (1)
LOW (0)
ECSx
: X6/SI1
ü
t [s]
100 %
0 %
t [s]
HIGH (1)
LOW (0)
ECSxK: X26 (24 V DC)
t [s]
HIGH (1)
LOW (0)
K1
U
ZK
1
ECSXK011
Fig. 4-3
Level/time diagrams for operation with other supplier
ECSx
Axis module of the ECS series
U
DCbus
DC-bus voltage
ECSxK
Capacitor module of the ECS series
K1
Mains contactor