Diagnostics, Troubleshooting and fault elimination – Lenze EVF9333−xV User Manual

Page 33

Advertising
background image

Troubleshooting and fault elimination

Display of operating data, diagnostics

Diagnostics

4

l

33

EDKVF93−03 EN 3.0

IMPORTANT

Possible settings

Code

Selection

Lenze

Name

No.

C0064

Utilization

0

{1 %}

150 Device utilisation I×t

l

Read only

l

Device utilisation during the last
180 s of operating time

l

C0064 > 100 % releases warning

OC5

l

C0064 > 140 % limits the output
current of the controller to 67 % of
the maximum current in C0022

C0150

Status word

Bit00

Bit08

Status code

Read only
Decimal status word for networking
via automation interface (AIF)

l

Binary interpretation indicates the
bit states

Bit01

IMP

Bit09

Status code

Bit02

Bit10

Status code

Bit03

Bit11

Status code

Bit04

Bit12

Warning

Bit05

Bit13

Message

Bit06

n = 0

Bit14

Bit07

CINH

Bit15

4.1.2

Diagnostics

Description

Display codes for diagnostics

Codes for parameter setting

Code

Possible settings

IMPORTANT

No.

Name

Lenze Selection

C0093 DRIVE IDENT

Controller identification

l

Read only

0

invalid

Damaged power section

1

none

No power section

9321
...
9333

9321VC
...
9333VC

Display of the controller used

C0099 S/W version

x.y

Software version

l

Read only

x
y

Main version
Subversion

Advertising