2 wiring of the system bus (can), Wiring of the system bus (can), Electrical installation – Lenze EPM−H507 User Manual

Page 66

Advertising
background image

Electrical installation

Wiring of the system bus (CAN)

4

l

66

EDBPM−H505 DE/EN/FR 6.1

4.2

Wiring of the system bus (CAN)

)

Note!

ƒ

Only connect terminals of the same signal type.

ƒ

For further information with regard to the system bus (CAN)
please refer to the CAN Communication Manual.

Shield

CAN-

-V

CAN+ N.C.

CG LO HI

CG LO

CG LO HI

CG LO HI

HI

120

120

A

n

A

2

(H505)

A

1

h505_002

Fig. 4−2

Wiring of system bus (CAN)

A

1

Node 1

A

2

Node 2

A

n

Node n

For the use of the transmission cable, follow our recommendations:

Specification of the transmission cable

Total length

£ 300 m

£ 1000 m

Cable type

LIYCY 2 x 2 x 0.5 mm2
(paired with shielding)

CYPIMF 2 x 2 x 0.5 mm

2

(paired with shielding)

Cable resistance

£ 80 W/km

£ 80 W/km

Capacitance per unit
length

£ 130 nF/km

£ 60 nF/km

Advertising
This manual is related to the following products: