Status display, Commissioning – Lenze EMF2141IB 2141 LON User Manual
Page 40

5
Commissioning
Status display
EDKMF2141 DE/EN/FR 2.0
L
40
Pos
LED status
Explanation
-20-
1
Green bus LED (voltage supply)
1
ON
Communication module is supplied with voltage and connected to the
controller.
OFF
Communication module is not supplied with voltage. The drive controller
or external voltage supply is switched off.
BLINKING
Communication modul is supplied with voltage but has not (yet) been
connected to the controller because
l
the communication module has not been plugged onto the controller
properly.
l
the data transfer of/to the drive controller is still not possible (e. g. the
drive controller is in the initialisation phase).
2
Yellow bus LED (communication)
2
OFF
Communication module has not been initialised yet.
BLINKING
LON communication active
3
Red and green drive LED indicate the operating mode of the drive controller 82XX or
93XX (see the Operating Instructions of the drive controller)
4
Service LED
4
OFF
Normal operating status
BLINKING
Communication module has not been configured yet
ON
Not program available in Neuron.
Show/Hide Bookmarks