6 mounting the fixed cover, 7 foot mounting, Mounting the fixed cover – Lenze g500-S Shaft-mounted helical gearbox User Manual
Page 25: Foot mounting, Mechanical installation
![background image](/manuals/566224/25/background.png)
Mechanical installation
Mounting
Mounting the fixed cover
EN
25
Lenze ¯ MA 12.0013 ¯ 1.0
4.4.6
Mounting the fixed cover
)
Note!
This cover is supplied loose on delivery!
X
X
Clip the protection cover into the bores, 6 x flange side, 4 x motor side.
4.4.7
Foot mounting
The foot on the g500−S130
S660 gearboxes can be mounted in three positions (3, 4,
5) using the supplied screws. It is mounted on side 6 using 4 screws and additionally on
side 1 using 2 screws. The screws must be mounted according to the hole pattern on the
foot (see figure) depending on the foot position.
Mounting order: depending on the mounting situation and installation space, the foot
can first be screwed to the machine housing and then to the gearbox or vice versa. The
foot can be mounted to the machine using studs or screws (not included in the scope of
supply).
Aligning the gearbox with the foot: independent of the mounting order, the gearbox
must be aligned with the machine shaft.
Gearbox type / size
Tightening torque
[ Nm ]
g500−S130 + g500−S220
10.1
g500−S400 + g500−S660
48