Diagnostics – Lenze ECSCMxxx User Manual
Page 256

Diagnostics
Diagnostics with Global Drive Oscilloscope (GDO)
Diagnostics with GDO
l
256
EDBCSXM064 EN 11.0
7. Select the variables the values of which are to be recorded during positioning .
– Double−click on the yellow text box "Variable" in the group box "Vertical".
– Select the variables in the dialog box appearing now.
– The values of up to 8 variables can be displayed in the graph box.
ECSXA563
Fig. 10−7
GDO view: Variable selection
8. Click on the [ START ] button to perform a positioning process.
ECSXA564
Fig. 10−8
GDO view: Performing a positioning process
System variables
The meaning of the most important variables is shown in the following table:
Variable
Data type
Signal
type
Code
Display
format
Description
AIF1_wDctrlCtrl
Word
˘
˘
˘
Control word (
^ 131)
AIF1_wDctrlStat
Status word (
^ 134)
AIF1_dnInD1_p
double
Integer
Position
˘
˘
Set position [inc]
65536 inc = 1 revolution
AIF1_dnOutD1_p
double
Integer
Position
˘
˘
Actual position [inc]
65536 inc = 1 revolution
Brake.L_BRK1.bSet_b
BOOL
binary
˘
˘
Demands on brake logic
Brake.L_BRK1.bOut_b
BOOL
binary
˘
˘
Set brake
CAN1_wDctrlCtrl
Word
˘
˘
˘
Control word (
^ 131)
CAN1_wDctrlStat
Status word (
^ 134)
CAN1_dnInD1_p
double
Integer
Position
˘
˘
Set position [inc]
65536 inc = 1 revolution