Diagnostics – Lenze ECSCMxxx User Manual

Page 256

Advertising
background image

Diagnostics

Diagnostics with Global Drive Oscilloscope (GDO)
Diagnostics with GDO

10

l

256

EDBCSXM064 EN 11.0

7. Select the variables the values of which are to be recorded during positioning .

– Double−click on the yellow text box "Variable" in the group box "Vertical".
– Select the variables in the dialog box appearing now.
– The values of up to 8 variables can be displayed in the graph box.

ECSXA563

Fig. 10−7

GDO view: Variable selection

8. Click on the [ START ] button to perform a positioning process.

ECSXA564

Fig. 10−8

GDO view: Performing a positioning process

System variables

The meaning of the most important variables is shown in the following table:

Variable

Data type

Signal

type

Code

Display

format

Description

AIF1_wDctrlCtrl

Word

˘

˘

˘

Control word (

^ 131)

AIF1_wDctrlStat

Status word (

^ 134)

AIF1_dnInD1_p

double

Integer

Position

˘

˘

Set position [inc]
65536 inc = 1 revolution

AIF1_dnOutD1_p

double

Integer

Position

˘

˘

Actual position [inc]
65536 inc = 1 revolution

Brake.L_BRK1.bSet_b

BOOL

binary

˘

˘

Demands on brake logic

Brake.L_BRK1.bOut_b

BOOL

binary

˘

˘

Set brake

CAN1_wDctrlCtrl

Word

˘

˘

˘

Control word (

^ 131)

CAN1_wDctrlStat

Status word (

^ 134)

CAN1_dnInD1_p

double

Integer

Position

˘

˘

Set position [inc]
65536 inc = 1 revolution

Advertising