Commissioning – Lenze ECSCMxxx User Manual
Page 95

Commissioning
Commissioning steps (overview)
Basic settings with GDC
l
95
EDBCSXM064 EN 11.0
Detailed
information
Brief description
Settings
9.
Set feedback system.
l
Set Lenze motors with resolvers (standard) in the GDC
parameter menu under Short setup
W Feedback system.
l
Set other resolvers and encoders in the GDC parameter
menu under Motor/feedback systems
W Feedback
system.
^ 109
10. Select the control interface.
l
Set C4010 in the GDC parameter menu under Short
setup
W Control/operating mode.
^ 130
11. Set toggle bit monitoring.
Set the following codes in the GDC parameter menu under
Motion
W Toggle bit monitoring:
l
C3160 (toggle bit error handling)
l
C3161 (toggle bit error counter limit)
^ 136
12. A Set signal assignment of
the digital inputs.
Set C4011 in the GDC parameter menu under Short setup
W
Digital inputs/outputs:
l
0: Control via the CAN interface X4 (MotionBus)
l
1: Control via the AIF interface X1 (for EtherCAT only)
^ 140
B Set the polarity of the
digital inputs and outputs.
l
Set IC0114/x (polarity X6/DI1 ... DI4) in the GDC
parameter menu under Terminals I/O
W Digital inputs.
l
Set C0118/1 (polarity X6/DO1) in the GDC parameter
menu under Terminals I/O
W Digital outputs.
^ 142
13. Enter machine parameters.
Set the following codes in the GDC parameter menu under
Motion
W Machine parameters:
l
C0011 (max. speed)
l
C0105 (deceleration time for quick stop (QSP))
l
C0596 (max. system speed)
l
C3030 (following error warning limit)
l
C3031 (following error limit FAIL−QSP)
l
C3032 (1st response when following error limit has been
reached)
l
C3033 (2nd response when following error limit has been
reached)
^ 138
14. Switch on the mains.
l
Green LED is blinking and red LED is off:
– Controller is ready for operation.
l
Green LED is off and red LED is blinking:
– An error has occurred. Eliminate the error before you
continue commissioning.
The basic settings are completed now.
Proceed as follows:
ƒ
Enable controller (
^ 183).
ƒ
Save parameters in the controller with C0003 = 1.
ƒ
Save parameter set with GDC in the parameter set file.
ƒ
Set homing (
^ 96).