Drive control & communication – Lenze MC Series Drives Modbus Communications User Manual

Page 30

Advertising
background image

RG-MCMOD 26

Drive Control & Communication

NOTE 4 - Acceleration Limits

Acceleration Limits

HP

Adjustment Range

.025 - 20

1 - 36000 (0.1 - 3600 sec)

25 - 60

3 - 36000 (0.3 - 3600 sec)

NOTE 5 - Deceleration Limits

Deceleration Limits

HP

Adjustment Range

240/200 VAC

480/400 VAC

590/480 VAC

without dB

with dB

0.25 - 7.5

1 - 7.5

3 - 36000 (0.3 - 3600 sec)

1 - 36000 (0.1 - 3600 sec)

10 - 15

10 - 20

1 - 7.5

5 - 36000 (0.5 - 3600 sec)

1 - 36000 (0.1 - 3600 sec)

20 - 30

25 - 60

10 - 20

10 - 36000 (1.0 - 3600 sec)

2 - 36000 (0.2 - 3600 sec)

25 - 60

20 - 36000 (2.0 - 3600 sec)

2 - 36000 (0.2 - 3600 sec)

NOTE 6 - MAX FREQUENCY (Register 62)

The Maximum limit is 650 Hz on drives with high frequency software.

NOTE 7 - MAX DC BRAKE VOLTAGE (Register 63)

Maximum DC Brake Voltage

Model

M3100/M1100

M3200/M1200

M3400/M1400

M3500/M1500

Voltage

240/120 Vac

240/200 Vac

480/400 Vac

590/480 Vac

MAX Brake Voltage

24 V

24 V

48 V

59 V

NOTE 8 - CURRENT (Register 67)

If LINE VOLTS, Register 51, is set to LOW (or set to Auto an the input voltage is low), the range for CURRENT
is 25 - 150%.

NOTE 9 - FX BOOST (Register 70)

FX BOOST Factory Default Settings

HP

All Models

HP

480/400 Vac
590/480 Vac

240/200Vac

0.25 - 1

5.30%

25

1.80%

1.80%

1.5 - 2

4.40%

30

1.60%

1.60%

3

3.60%

40

1.20%

2.30%

5

3.00%

50 - 60

0.80%

2.10%

7.5

2.70%

75

2.00%

N/A

10

2.40%

100 -125

1.90%

N/A

15

2.20%

150

1.80%

N/A

20

2.00%