9400 Technology applications | Synchronism with mark synchronisation
Parameter setting & configuration
"Synchronism" mode"
TP profile parameters
r
Parameter setting: Tab Application parameters dialog level Overview TP profile
parameters
r
Configuration: Tab FB editor FB
TP interface
r
Parameter setting: Tab Application parameters dialog level Overview TP interface
Parameter
Lenze setting
Value Unit
C03620
Positioning mode
0
C03621
Deactivation mode
0
C03623/1
Positive speed
3600.0000 unit/t
C03623/2
Negative speed
3600.0000 unit/t
C03626/1
Acceleration ramp
1.000 s
C03626/2
Deceleration ramp
1.000 s
C03626/3
Stop ramp
1.000 s
Control inputs of the function
Signal configuration
Lenze setting
Control input
(Multiplexer parameters)
FALSE Activate master value TP correction
C03058/12
Parameter
Lenze setting
Value Unit
C02810/3
Signal delay TP3
0 μs
C03022
Edge evaluation of positive edge
TRUE
C03024
Edge evaluation of negative edge
FALSE