Parameterisable function blocks
This subchapter lists all relevant parameterisable function blocks of the technology
application and the corresponding parameters in alphabetical order.
4.14.1
ApplicationError
Is an instance of
Function
L_DevApplErr
Error handling
Application error messages (C 53)
Parameter
Possible settings
Information
C05900
980
999 Module ID
• Initialisation: 999
C05901/1...8
0
65535 Error ID
• Initialisation: 8001 ... 8008
C05902/1...8
Error response
0 None
1 Fault
2 Trouble
3 Quick stop by trouble
4 Warning locked
5 Warning
6 Information