3 virtual clutch – Lenze E94AxHE Technology Application Synchronism User Manual
Page 36

9400 Technology applications | Synchronism with mark synchronisation
Parameter setting & configuration
"Synchronism" mode"
36
L
EDS94TA10040xxxx EN 1.1 - 10/2008
4.5.3
Virtual clutch
[4-7]
Function "Virtual clutch" in the signal flow (schematic diagram)
r
Parameter setting: Tab Application parameters dialog level Overview Virtual clutch
r
Configuration: Tab FB editor FB
n
Master value with stretch factor
o
Master value with clutch
M
v
Slave
Real master/
Virtual master
C03006 = 0
v
t
Dj
Dj
Dj
TP
TP
Parameter
Lenze setting
Value Unit
C03672
Master value with stretch factor
- unit
C03021
Activate clutch
Deactivated
C03665/1
Clutch in ramp
1.000 s
C03665/2
Decoupling ramp
2.000 s
C03665/3
Ramp for positive opening operation
1.000 s
C03674
Master value with clutch
- unit
C03679
Standstill position selection
0.0000 unit
Control inputs of the function
Signal configuration
Lenze setting
Control input
(Multiplexer parameters)
DIGIN 4 Close clutch
C03058/13
FALSE Clutch - positive opening operation
C03058/14