7 "manual jog" mode – Lenze E94AxHE Technology Application Synchronism User Manual
Page 42

9400 Technology applications | Synchronism with mark synchronisation
Parameter setting & configuration
"Manual jog" mode
42
L
EDS94TA10040xxxx EN 1.1 - 10/2008
4.7
"Manual jog" mode
In the "Manual jog" mode (C03006 = "4") the drive is decoupled from the electrical shaft
and the basic function "Manual jog" is enabled:
[4-12] "Manual jog" mode (schematic diagram)
r
Parameter setting: Tab Application parameters dialog level Overview Manual jog
v
t
LS_ManualJog
n
t
и
з
n
t
LS_Positioner
0
-100
100 200
LS_Homing
C03006 = 4
t
M
Slave
Parameter
Lenze setting
Value Unit
C02620
Manual jog: Speed 1
360.0000 unit/s
C02621
Manual jog: Speed 2
720.0000 unit/s
C02622
Manual jog: Acceleration
360.0000 unit/s
2
C02623
Manual jog: Deceleration
1440.0000 unit/s
2
C02624
Manual jog: S-ramp time
0.100 s
C03007
Positive manual jog
Inactive
C03008
Negative manual jog
Inactive
Control inputs of the function
Signal configuration
Lenze setting
Control input
(Multiplexer parameters)
C03007 Activate positive manual jog
C03155/2
C03008 Activate negative manual jog
C03155/3
FALSE Activate 2. speed
C03155/4
FALSE Retract limit switch
C03155/5