15 limittpdiffshaft, 16 limittpdifftool – Lenze E94AxHE Technology Application Synchronism User Manual
Page 63

EDS94TA10040xxxx EN 1.1 - 10/2008
L
63
9400 Technology applications | Synchronism with mark synchronisation
Parameter setting & configuration
Parameterisable function blocks
4.14.15
LimitTPDiffShaft
4.14.16
LimitTPDiffTool
Is an instance of
Function
L_SdSetPosition
Mark synchronisation (master value):
Conversion of the TP limit selected in the real units of the machine via C03651 into
a position in [increments].
Mark synchronisation (master value) (C 34)
Parameter
Possible settings
Information
C03651
-214000.0000
unit
214000.0000 Position value
• Initialisation: 0.0000 unit
C03652
String of digits
Position unit
• Read only
C03653
-2147483647
2147483647 Status
• Read only
Is an instance of
Function
L_SdSetPosition
Mark synchronisation (setpoint):
Conversion of the TP limit selected in the real units of the machine via C03851 into
a position in [increments].
Mark synchronisation (setpoint) (C 39)
Parameter
Possible settings
Information
C03851
-214000.0000
unit
214000.0000 Position value
• Initialisation: 0.0000 unit
C03852
String of digits
Position unit
• Read only
C03853
-2147483647
2147483647 Status
• Read only