4 counting only once: no main counting direction, L-force controls | i/o system 1000 – Lenze L-force I/O System 1000 User Manual
Page 51

2.0 EN - 11/2010
L
51
L-force Controls | I/O System 1000
Parameter setting
Electronic modules - counters
6.6.4
Counting only once: No main counting direction
Function:
The counter starts counting up or down only once within a defined counting range.
In the case of an overflow / underflow of the counting limit values, the counter jumps
to the respective other counting limit value and the counter will stop automatically. A
process alarm is triggered provided that it has been enabled.
"Pause" gate function: The counting process is continued with the current counter
content.
"Cancel" gate function: The counter starts with the start value.
[6.2]
Example of "Counting only once", no main counting direction, and with interruptive gate control
[6.3]
Example of "Counting only once", no main counting direction, and with cancelling gate control
Limits
Counting range
Lower counting limit -2 147 483 648 (-2
31
)
Upper counting limit +2 147 483 647 (-2
31
-1)