Model 505.20 - 505.30 SilentFlo™ HPU

18

505.20/.30 HPU Hydraulic Schematic

Introduction

505.20/.30 HPU Hydraulic Schematic

The hydraulic schematic shows the functional layout of the Series 505 Hydraulic
Power Unit.

Water

Shutoff

Valve

Water

Regulator

Valve

Heat

Exchanger

Sight

Gage

Temperature

Gage

Pump Drain

Check Valve

0.014 MPa (2.0 psi)

Pump Drain

Check Valve

0.034 MPa

(5.0 psi)

3 Micron

Filter

Reservoir

Pump

Motor

Surge

Suppressor

Temperature and

Low Level

Sensor

Control Manifold

Pressure

Gage

Oil Sample

Port

Accumulator

(optional)

Pressure Filter

(optional)

Auto-cooling

Valve

(adjustable)

Check

Valve

High Pressure

Solenoid Valve

Auto-cooling

Valve

(factory set)

Accumulator

P

R

D

W

W

0.063 inch Orifice

0.007 MPa (1.0 psi)

Pressure

Relief Valve

(factory set at

22.4 MPa

(3250 psi)

Advertising