22

505.20/.30 HPU Specifications

Introduction

Model Specific Specifications

Parameter

505.20 Specification

505.30 Specification

Pump/Motor

Maximum continuous
pressure

Maximum flow
capacity

Motor rating

Current draw

Operating voltages

Control voltage

Type NEMA compliant

21 MPa (3000 psi)

75 L/m (20 gpm) at 60 Hz
62 L/m (16.5 gpm) at 50 Hz

30 kW (40 hp) at 50/60 Hz

52 A continuous at 460 V AC 3Ø
66 A continuous at 380 V AC 3Ø

200–575 V AC

24 V DC

Type NEMA compliant

21 MPa (3000 psi)

113 L/m (30 gpm) at 60 Hz
101 L/m (26.6 gpm) at 50 Hz

45 kW (60 hp) at 50/60 Hz

77 A continuous at 460 V AC 3Ø
97 A continuous at 380 V AC 3Ø

200–575 V AC

24 V DC

Water flow rating
(input temperature)

15.5°C (60°F)

21.1°C (70°F)

26.7°C (80°F)

32.2°C (90°F)

Heat load (maximum)

23.4 L/m (6.26 gpm)

30.2 L/m (8.06 gpm)

42.7 L/m (11.3 gpm)

60.4 L/m (16 gpm)

31.65 kW (108,000 Btu/hr)

35.2 L/m (9.3 gpm)

45.4 L/m (12 gpm)

64.7 L/m (17.1 gpm)

91.2 L/m (24 gpm)

49.2 kW (168,000 Btu/hr)

Weight

Empty

With 227 L (60 gal) oil

542 kg (1195 lb)

733 kg (1615 lb)

588 kg (1295 lb)

778 kg (1715 lb)