Adjusting the Auto-Cooling Level

Operation

3. Adjust the Auto-cooling Valve by slowly turning the valve counter

clockwise. When the valve shifts, a sudden change in pitch will be heard
from the pump.

A.

Reversing the valve adjustment a number of times will aid in
identifying the proper setting.

B.

Make a final counter-clockwise adjustment, an increase in pump pitch
will be heard that corresponds with the opening of the valve.

C.

Stop adjusting at this point.

4. Confirm the auto-cooling valve setting by slowly cycling the HPU Output

Pressure Control. Decrease the HPU output pressure and note a decrease in
pump pitch when the valve closes.

A.

At the point when the valve closes the pressure on the gage will
momentarily hesitate during the adjustment.

B.

Increase the pump output pressure to the desired pressure setting and
note an increase in pump pitch when the valve opens. Once again the
pressure gage will show a momentary hesitation when the valve opens.

5. If necessary, repeat Steps 2 and 3 until the auto-cooling valve is stable and

the HPU cools properly.

6. After the final adjustment, hold the HPU Output Pressure Control to

prevent it from moving while tightening the nut to secure the setting.

7. Verify the output pressure remained at the desired level.

8. Hold the Auto-cooling Valve stem to prevent it from turning while

tightening the nut to secure the setting.