Precharging the Surge Suppressor Accumulator

Installation

3. With an open-end wrench, turn the locknut counterclockwise on the

accumulator valve assembly to open the valve. Read the pressure on the
high pressure gage.

If the pressure reading is outside the range of 10.3–12.5 MPa (1500–
1800 psi), refer to the procedure on changing the precharge pressure.

If the pressure level is within the range of 10.3–12.5 MPa (1500–1800
psi), turn the locknut clockwise to close the valve and continue this
procedure.

4. Open the bleed valve on the accumulator charging kit and remove the chuck

valve from the accumulator. Replace the valve stem cap and protective
cover on the accumulator.

Charging Kit

Changing the

precharge pressure

The nitrogen precharge should be within the range of 10.3–12.5 MPa (1500–
1800 psi) which is 50–60% of the output pressure (21 MPa or 3000 psi). Perform
one of the following procedures to change the precharge pressure:

Decreasing pressure

To decrease the precharge pressure:

1. Slowly open the bleed valve on the charging kit until gas begins to escape.

When the pressure reading on the appropriate pressure gage drops to the
level required, close the bleed valve.

2. Close the locknut. Open the bleed valve on the accumulator charging kit and

remove the chuck valve from the accumulator.

High Pressure Gage
0–21 MPa (0–3000 psi)

Gage Protector
(factory set to limit
pressure to the gage to
approximately 1.4 MPa
(200 psi)

Extension Hose

Bleed Valve

Input Check
Valve

Nitrogen Supply Hose

Regulator Output
Pressure Gage

Nitrogen Bottle
Pressure Gage

Core-Type Valve

To Open and Close Use

Chuck Valve

Nitrogen
Bottle

Nitrogen
Bottle Valve

Regulator Output
Pressure Valve

Regulator Shut-
Off Valve

You must supply these items:

Check Valve

Locknut

Valve Stem

Open

Close

Poppet-Type Valve

To Open and Close Use

Chuck Valve

Close

Valve Stem

Valve Core

Open

Open

Close

Low Pressure Gage
0–2.1 MPa (0–300 psi)