II.C. Installing Faucet with Capacity Monitor

(continued)

Installation of the Capacity Monitor

1. Preparing the Filter Monitor Box (#15):

a. Guide the black wire (# 7) from under the sink to the Filter Monitor Box (#15) and connect the

two plugs.

b. Open the Filter Monitor Box and pull out the battery holder. Then insert two AAA batteries (not

included), matching polarity shown on the battery holder. Press the check/reset button for six
seconds. There will be a long audio sound, and the LED on the Capacity Indicator Plate will
flash red and then green several times.

c. Snap the cover back onto the Filter Monitor Box.
d. Peel off the paper backing from the Velcro® and attach one piece to the back of the

Filter Monitor Box. Select a clean, convenient location to mount the Box on your cabinet wall
under the sink, allowing sufficient space for placement of the capacity flow device (#14) which
is attached by a wire to the Filter Monitor Box. Press the second piece of Velcro® to the cabi-
net wall and press the Box onto the wall. .

2. Preparing the Capacity Flow Device (#14):

a. Attach the two adapters (#16) to the capacity flow device (#14) -- one on each

side.

b. Complete the installation after connecting the tubing (see next step).

Connecting the Tubing

(See Section V.A for tips on connecting tubing)

Faucet Connection:

Connect the blue tubing attached to the faucet to the adapter (#16) on the OUTLET
(faucet) (#5) side of the Capacity Flow Device (see the arrow on the Device for the
direction of the water flow.)
1. Using wire cutters or knife, cut (square cut) the tip end off of the blue plastic tube

connected to the faucet. Do not use scissors.

2. The tubing must be fully inserted in the adapter. It is recommended that you measure

and mark the end of the tubing that you are inserting in the adapter to assure that it is
inserted as far as it will go. The 1/4” blue tubing should be inserted about 5/8”.

3. Push the tubing through the small hole in the adapter until you feel resistance; at this

point, the tubing is not fully inserted. Then push firmly until the tubing is inserted as
far as it will go (see Item 2 above for measurement).

Housing Connection:
NOTE: A separate piece of blue tubing is included with your shipment. Attach this separate
piece of tubing between the housing OUTLET port and the Capacity Flow Device INLET port.
Read this section first and then complete the installation of your drinking water system
(See Section V.A and V.B).

When you have completed the installation of your drinking water system below your sink, then con-
nect the separate piece of blue tubing (#17) to the small straight adapter that you previously attached
to the OUTLET port of the housing and then to the adapter on the INLET side of the Capacity Flow
Device.

1. Using wire cutters or knife, cut (square cut) the tips off of both ends of the plastic tube

to be connected between the housing OUTLET port and the Capacity Flow Device
INLET port. Do not use scissors.

2. The tubing must be fully inserted in the adapters. It is recommended that you measure

and mark the end of the tubing that you are inserting in the adapter to assure that it is
inserted as far as it will go. The 1/4” tubing should be inserted about 5/8”.

3. Push the tubing through the small hole in the adapters until you feel resistance; at

this point, the tubing is not fully inserted. Then push firmly until the tubing is inserted
as far as it will go (see Item b above for measurement).

Plug

Plug

To filter

monitor box

To capacity
indicator plate

14

16

5

16

17

Capacity Flow Device Assembly

OUTLET
to faucet

INLET

from housing

Insert blue tubing 5/8”

tubing

Adapter

OUTLET

insert

Insert tubing and push

until you feel resistance

-- at this point, the

tubing is not fully

inserted. Push firmly

until the tubing is

inserted as far as

it will go.

Pull to check that the

tubing is secure.

Advertising