INSPECTION - BLADE PLACEMENT

1. Blade Guard – Raise the front half of the blade guard to

expose the blade shaft nut & outer flange.

2. Blade Nut Wrench – Remove the blade nut wrench (3) from

the tool holder and unscrew the blade shaft nut (right-side).
This nut

loosens clockwise

and

tightens counter-

clockwise

.

Figure 12. Diamond Blade Placement

5.

Blade Pin Hole – Align this hole with the drive pin hole on
the inner flange collar.

6.

Diamond Blade – Ensure that the proper blade has been
selected for the job. Pay close attention to the directional
arrow on the blade,

clockwise for right-side

cutting,

counter-clockwise for left-side

cutting. The arbor hole

of the blade must match the 1" arbor of the blade shaft.

7.

Inner Flange Collar – This flange is fixed upon the blade
shaft, and is manufactured with a drive pin hole. The inside
surface of the flange must be free of debris and permit a
tight closure on the surface of the blade.

3.

Blade Nut – Remove the blade nut (4). For reassembly,
DO NOT over tighten the blade nut against the outer flange.
Tighten blade nut approximately 62-69 N/m./45-50 ft-lbs.

4.

Outside Blade Flange (Collar) – Ensure that the flange
face is clean and free of debris and is placed flush against
the diamond blade (7). Check that the drive pin goes through
the blade pin hole (6) and seats properly into the inner
flange (8).