Electric start-up (20hp honda engine) – Multiquip SP2S20H20A User Manual
Page 32
PAGE 32 — SP213H20A / SP2S20H20A SAWS — OPERATION AND PARTS MANUAL — REV. #1 (05/17/10)
3. Ensure the diamond blade has been mounted correctly and
that it is raised above the surface you are about to saw.
4. If operating the SP2 saw in
cold weather conditions
, skip
this step and proceed to step 5. Place the
Choke Lever
(Figure 33) in the
OPEN
position. Skip to step 6.
The CLOSED position of the choke lever enriches the fuel mixture
for starting a COLD engine. The
OPEN position provides the correct
fuel mixture for normal operation
after starting, and for restarting a
warm engine.
NOTE
5. If operating the SP2 in
cold weather conditions
, place the
Choke Lever
(Figure 34) in the CLOSED position.
Figure 33. Choke Lever (Open Position)
Figure 34. Choke Lever (Closed Position)
6.
Place the
throttle lever
(Fig-
ure 35) halfway between FAST and SLOW for starting.
Figure 35. Throttle Lever (Fast Position)
7. Rotate the
Engine Shutdown switch
(Figure 36) to the
START position to engage the starter.
Figure 36. Ignition Switch (Start Position)
ELECTRIC START-UP (20HP HONDA ENGINE)
Figure 32. Engine Start Switch (OFF Position)
8. Once the engine has started, slowly return the choke lever
(Figure 34) to the CLOSED position. If the engine has not
started repeat steps 4 through 7.
9. Before the saw is placed into operation, place the
throttle
lever
in the FAST position and run the engine for several
minutes. Check for fuel leaks, and noises that would associ-
ate with a loose guard and/or covers.
10. All cutting is done at FULL THROTTLE. Your engine gover-
nor has been set at the factory to ensure an optimum speed
setting.
OR