Stow cs4030 saw — maintenance, Warning – Multiquip CS403030 User Manual

Page 48

Advertising
background image

PAGE 48 — STOW CS4030 SAW • OPERATION MANUAL — REV. #0 (12/13/07)

)

Figure 55. Blade Flange Puller

Correct removal or installation of the Inner Blade Flange requires
Flange Puller (p/n 18503) as shown in figure 55.

Blade Flange Removal/Installation

If unfamilar with this operation seek assistance or training
from someone that is familar with this operation. Because of
the tapered fit between the Blade Flange and Blade Shaft,
5-10 tons of force is required to release the inner flange from
the Blade Shaft. Both parts and tools can become dangerous
projectiles if instructions are not followed properly.

WARNING

WARNING

WARNING

WARNING

WARNING

Removing the Inner Blade Flange

1.

With the Outer Blade Flange in place, loosen the Blade
Mounting Bolt approximately 1/4".

2.

While the 3 perimeter bolts hold the two Puller Plates
together, slide the Horseshoe Plate of the Flange Puller
behind the (Shaft) side of the Inner Flange.

3.

Tighten the center puller bolt to remove the Inner Flange
from the Blade Shaft.

The Outer Flange MUST be in place to prevent the Puller
assembly and Inner Flange from flying off when the taper
breaks loose. Injury or equipment damage could otherwise
result.

WARNING

WARNING

WARNING

WARNING

WARNING

3.

Lock down the Wheel Mount Assembly Attachment Bolts
when the appropriate alignment distance is set.

Figure 54. Drive Wheel Alignment Bolt

Locations

1.

Pivot Attachment Bolt

2. Adjustment Attachment Bolts

3. Adjustment Screw

STOW CS4030 SAW — MAINTENANCE

1.

Blade Flange

2. Horseshoe Puller Plate

3. Puller Plate

4. Perimeter Bolt

5. Center Puller Bolt

3

1

2

1

2

4

5

3

Advertising