Enhanced Design for Superior Performance in Variable-Frequency Drives

600/1000 V Shielded

Series V cables for variable-frequency

drives (VFD) set the standard in high-

performance and reliable connectivity.

Their specially formulated cross-linked

polyethylene insulation provides superior

corona resistance, low capacitance

for longer runs, and excellent low-

temperature properties.
A symmetrical design places the ground

wires in the interstices of the conductors

for uniform conductor-to-ground

capacitance and impedance.
Smaller gauge cable feature a combination

foil/braid shield to offer exceptional

EMI/RFI protection in noisy environments.

On larger gauge cable, a double copper

tape is used to provide the same noise-

free operation.
This uniformity reduces the probability

of motor damage from common-mode

current.
Alpha Series V VFD cables are compatible

with drives from all major manufacturers.

UL RHW-2 (16 – 2 AWG)

UL XHHW-2

UL TC-ER

UL 1000V Flexible Motor

Supply Cable

CSA AWM I/II A/B FT4

CE LVD 73/23/EEC

Amendment 93/68/EEC

Pennsylvania MHSA

Operating Temperature

• -40°C to +90°C

Conductor Color Coding

• Black, numbered

Materials

• Stranded tinned copper

conductors

• Stranded tinned copper

ground wires

• Cross-linked polyethylene

insulation

• Shielding

16 – 4 AWG:

Aluminum/polyester/aluminum

foil and tinned copper braid

with 85% coverage

2 – 4/0 AWG:

Double-layer copper tape

• Black premium PVC jacket

Voltage

• 600 V (UL TC-ER)

• 1000 V (UL Motor Supply)

Features

• UL Direct Burial

• UL Sunlight Resistant

• 10x bend radius

• Suitable for use in Class I,

Division 2 locations per Article

501 of the National Electric Code

Availability

Bulk, made to order

FIT® Tubing Recommendations

• FIT-221: General-purpose

cross-linked polyolefin

• FIT-321V: Low-shrink-

temperature, flame-retardant

cross-linked polyolefin

Four-Conductor VFD Cable

Part No.

Wire Size

Stranding

Shielding

Insulation Thickness

Jacket Thickness

Nominal Diameter

AWG

mm

2

AWG

mm

Inch

mm

Inch

mm

Inch

mm

V16016

16

1.32

26/30

26 x 0.25

Foil/Braid

0.047

1.19

0.065

1.65

0.547

13.89

V16014

14

2.09

41/30

41 x 0.25

Foil/Braid

0.047

1.19

0.065

1.65

0.584

14.83

V16012

12

3.31

65/30

65 x 0.25

Foil/Braid

0.047

1.19

0.065

1.65

0.633

16.08

V16010

10

5.37

105/30

105 x 0.25

Foil/Braid

0.047

1.19

0.085

2.15

0.746

18.95

V16008

8

8.53

133/29

133 x 0.28

Foil/Braid

0.061

1.55

0.086

2.15

0.920

23.37

V16006

6

13.57

133/27

133 x 0.36

Foil/Braid

0.061

1.55

0.086

2.15

1.017

25.83

V16004

4

21.58

133/25

133 x 0.45

Foil/Braid

0.061

1.55

0.086

2.15

1.157

29.39

V16002

2

34.32

133/23

133 x 0.57

Foil/Braid

0.061

1.55

0.088

2.15

1.308

33.22

Four-Conductor VFD Cable with 14 AWG (2.09) Brake Pair

Part No.

Wire Size

Stranding

Shielding

Insulation Thickness

Jacket Thickness

Nominal Diameter

AWG

mm

2

AWG

mm

Inch

mm

Inch

mm

Inch

mm

V16116

16

1.32

26/30

26 x 0.25

Foil/Braid

0.047

1.19

0.065

1.65

0.717

18.21

V16114

14

2.09

41/30

41 x 0.25

Foil/Braid

0.047

1.19

0.065

1.65

0.743

18.87

V16112

12

3.31

65/30

65 x 0.25

Foil/Braid

0.047

1.19

0.065

1.65

0.785

19.94

V16110

10

5.37

105/30

105 x 0.25

Foil/Braid

0.047

1.19

0.085

2.15

0.875

22.23

V16108

8

8.53

133/29

133 x 0.28

Foil/Braid

0.061

1.55

0.085

2.15

1.032

26.21

Advertising