Series m control cable – Northern Connectors Alpha Wire Communication, Control & Industrial Cable User Manual

Page 8

Advertising
background image

Alpha Wire | www.alphawire.com | 1-800-52 ALPHA

Specifications subject to change. For complete specifications and availability, visit www.alphawire.com.

280

Cable > Communication, Control and Industrial > Multiconductor > Unshielded > 600 V

Series M Control Cable

Stationary or Minimal Flex Applications

600 V Unshielded, Multiconductor

UL TC-ER

UL MTW

UL WTTC (1000 V)

UL PLTC (300 V)

CSA AWM I/II A/B FT4

CE LVD 73/23/EEC Amend.

93/68/EEC

Operating Temperature

• -25°C to +90°C (static)

• -5°C to +90°C (dynamic)

Conductor Color Coding

• Red, blue, or black insulation*,

numbered

1 green/yellow green conductor

1 white-striped neutral

(12 conductors or greater,

except 14 AWG)

Materials

• Finely stranded bare copper

conductors

• PVC/nylon insulation

• Slate PVC jacket

Features

• UL Sunlight Resistant

• UL Oil Res. I

• UL Direct Burial

• Suitable for use in Class I,

Division 2 locations per Article

501 of the National Electric Code

• 90°C Dry/75°C Wet

Availability

Bulk, cut to length

FIT® Tubing Recommendations

• FIT-221: General-purpose

cross-linked polyolefin

• FIT-321: Medium-wall, adhesive-

lined cross-linked polyolefin

14 AWG (2.09 mm

2

)

Stranding: 41/30 (41 x 0.25 mm)

Insulation thickness: 0.016 (0.41 mm) PVC/0.005 (0.10 mm) nylon

Part No.

Conductors

Nominal

Diameter

Jacket

Thickness

Black Insul.

Blue Insul.

Red Insul.

Inch

mm

Inch

mm

M14104KW M14104LW M14104RW

4

0.384

9.75

0.050

1.27

M14105KW M14105KW M14105RW

5

0.428

10.87

0.055

1.39

M14107KW M14107LW

M14107RW

7

0.483

12.26

0.065

1.65

M14112KW

M14112LW

M14112RW

12

0.615

15.62

0.065

1.65

M14125KW

M14125LW

M14125RW

25

0.887

22.52

0.085

2.15

12 AWG (3.31 mm

2

)

Stranding: 65/30 (65 x 0.25 mm)

Insulation thickness: 0.016 (0.41 mm) PVC/0.005 (0.10 mm) nylon

Part No.

Conductors

Nominal

Diameter

Jacket

Thickness

Black Insul.

Blue Insul.

Red Insul.

Inch

mm

Inch

mm

M12104KW M12104LW M12104RW

4

0.44

11.17

0.055

1.39

M12105KW M12105LW

M12105RW

5

0.499

12.67

0.065

1.65

M12107KW M12107LW

M12107RW

7

0.540

13.71

0.065

1.65

10 AWG (5.32 mm

2

)

Stranding: 105/30 (105 x 0.25 mm)

Insulation thickness: 0.022 (0.56 mm) PVC/0.005 (0.10 mm) nylon

Part No.

Conductors

Nominal

Diameter

Jacket

Thickness

Black Insul.

Blue Insul.

Red Insul.

Inch

mm

Inch

mm

M10104KW M10104LW M10104RW

4

0.549

13.94

0.065

1.65

M10105KW M10105LW M10105RW

5

0.600

15.24

0.065

1.65

M10107KW M10107LW M10107RW

7

0.652

16.56

0.065

1.65

8 AWG (8.52 mm

2

)

Stranding: 168/30 (168 x 0.25 mm)

Insulation thickness: 0.032 (0.81 mm) PVC/0.006 (0.15 mm) nylon

Part No.

Conductors

Nominal

Diameter

Jacket

Thickness

Black Insul.

Blue Insul.

Red Insul.

Inch

mm

Inch

mm

M08104KW M08104LW M08104RW

4

0.724

18.38

0.065

1.65

M08105KW M08105LW M08105RW

5

0.795

20.19

0.065

1.65

* Red insulation: AC circuits operating at less than line voltage

Blue insulation: DC circuits operating at less than line voltage

Black insulation: AC circuits operating at less than line voltage

Advertising