Connect safety device – Retsch AS 200 tap 30.025.0001 User Manual

Page 14

Advertising
background image

08.01.2008

Retsch GmbH

14

Doc.Nr. D 98.025.9999

Connect Safety Device

When installing the AS 200 tap, special attention
must be paid to mounting the protective devices
correctly in order to meet the requirements of the
harmonised EN292-1 standard.

Depending on the safety device selected either the
PS safety plug can be fitted or the local safety de-
vices can be connected with the aid of the safety
socket.
Make sure that if the PS safety plug is being used on
its own the operator is protected from any inadver-
tent reaching into the machine.


Remove the Pa (red) cover and replace

it with the Ps safety plug (green).

Other safety devices can be connected to this socket
by trained personnel.

On delivery the machine is in P1 mode program (see
adjacent picture).

After the connection of an external safety device,
the Start T2 (M) pushbutton can be deactivated by
switching over to program mode P2.

Turn off the machine.

While keeping the two TIME + - buttons
pressed down, switch on the machine.

Press the STOP button to save the program
mode.

The software is now set to the P2 program mode. P2
appears in the display.

Pa

Pa (rot)

Ps (grün)

T1

T1

T2

P1

P2

T1

T1

T2

PS

Advertising