33 • Maintenance

Model GX-2001 Operator’s Manual

Replacing the Battery Pack

WARNING: Replace the battery pack in a non-hazardous

environment.

Replace the battery pack when it no longer holds a charge.

1. Verify that the Model GX-2001 is off.

2. On the left or right side of the Model GX-2001, unscrew two of the

screws securing the belt clip retaining pins to the unit.

3. Carefully slide out the small pins holding the belt clip to the unit by

grasping them with your fingers.

4. Unscrew the four screws holding the metal plate to the back of the

Model GX-2001, then remove the plate.

5. Carefully press on the upper tab of the battery with a small flat blade

screw driver and gently pry up to remove the battery from the GX-
2001’s housing.

6. Replace the battery. Insert the bottom first so it snaps into place, then

the top.

Figure 7: Removing the Battery from the Model GX-2001

Re m ove
Pack F rom
T his End

1st: D epre ss This T ab

Shown Without Clip & Rear Cover Plate

2nd: Pull Battery O ut