Alarm indications – RKI Instruments Beacon 800 User Manual

Page 21

Advertising
background image

Beacon 800 Gas Monitor Operator’s Manual

Alarm Indications • 18

Alarm Indications

This section describes the Beacon 800 in alarm 1, alarm 2, and fail conditions, and
suggests responses to these conditions. Table 4 lists the alarm indications for each
condition.

NOTE: The Beacon 800 includes alarm on and alarm off delay settings for each channel

and level of gas alarm. The alarm indications described in this section operate
according to the default delay settings. See Chapter 5: Configuration Menu for
detailed information on displaying or changing the alarm on and alarm off delay
settings.

NOTE: You can set the channel relays to be normally energized or normally de-

energized in the Configuration menu. The following sections describe the default
setting: normally de-energized.

Common alarm 1 and alarm 2 relays are factory-set as normally de-energized,
and the common fail relay is factory-set for normally energized. The common
relays are not user adjustable.

Table 5: Visual and Audible Alarm Indications

Condition

Cause

Visual Indication(s)

Audible
Indication

Alarm 1

Increasing (decreasing for O

2

) gas

reading at or above the alarm 1
setpoint

ALARM 1 light is on

Gas reading flashes and
alternates with ALARM-1
message

Steady tone

Alarm 2

Increasing gas reading at or above
the alarm 2 setpoint

ALARM 1 and ALARM 2
lights are on

1

Gas reading flashes and
alternates with ALARM-1
and ALARM-2 messages

Steady tone

Fail

Disconnected or misconnected
transmitter wiring

Display reading below -10% of
fullscale or lower

Malfunctioning components

FAIL light is on

FAIL message flashes in
place of gas reading

Steady tone

Low
Battery

2

No AC power and DC power
source (primary or backup) less
than 21.5 volts.

FAIL light is on

Top screen displays
SUPPLY VOLTAGE IS
TOO LOW
message

Bottom screen displays -
LOW POWER
STANDBY-
message
and actual voltage of
incoming DC power

None

1

The ALARM 1 light is not on for oxygen channels.

2

If DC power is used as primary or backup power source.

Advertising