Do not inst all a t al titude above 6,800 f eet – Schwank bistroSchwank 2-Stage User Manual

Page 40

Advertising
background image

2100 / IO 100 Manual

IM110107

RD: MAY 2014

R.L. 4A

40

21. HIGH ALTITUDE INSTALLATION / DERATION

This heater not to be installed at altitude above 6,800 feet.

USA & Canada: The factory installed orifice for this appliance is approved for altitudes zero to 2000 feet
above sea level. When installed above 2000 feet, refer to information below.

When this appliance is installed above the standard altitude stipulated the input must be de-rated by 4% for each
1000 ft above sea level. The orifice must be changed according to the chart below - confirm the correct model.
Check with your local utility regarding the gas supply and the de-rating of this appliance.

1

As per ANSI Z223.1 (NFPA 54)

MODEL

FOR USE AT ALTITUDES ABOVE (FEET)

Gas Orifice Drill Size

1

/ Part #

Supplied

0

> 2000

> 3000

> 4000

> 5000

> 6000

DO NOT INST

ALL
A

T

AL

TITUDE ABOVE

6,800 F

EET

2135 / IO-135 NG

38 DMS

JX-0738-DM

41 DMS

JX-0741-DM

42 DMS

JX-0742-DM

42 DMS

JX-0742-DM

43 DMS

JX-0743-DM

43 DMS

JX-0743-DM

2135 / IO-135 LPG

50 DMS

JX-0750-DM

52 DMS

JX-0752-DM

53 DMS

JX-0753-DM

53 DMS

JX-0753-DM

53 DMS

JX-0753-DM

53 DMS

JX-0753-DM

2150 / IO-150 NG

31 DMS

JX-0731-DM

32 DMS

JX-0732-DM

32 DMS

JX-0732-DM

32 DMS

JX-0732-DM

33 DMS

JX-0733-DM

34 DMS

JX-0734-DM

2150 / IO-150 LPG

46 DMS

JX-0746-DM

48 DMS

JX-0748-DM

48 DMS

JX-0748-DM

49 DMS

JX-0749-DM

49 DMS

JX-0749-DM

49 DMS

JX-0749-DM

USA & CANADA ORIFICE DERATION

Advertising