PROBLEM

PROBABLE CAUSE

SOLUTION

Burner will not light

Gas valve may be in OFF position

Pilot Orifice blocked

Air in supply system

Loose connection

Electronic Igniter ‘AAA’ 1.5v

Battery Dead

1st time ignition

Igniter assembly bent/or not in the

correct position to ignite.

Igniter failure

Burner will not stay lit

Debris or dirt around the pilot

Loose connections

Thermocouple faulty

Gas leak in the line

Clean pilot area

Tighten Connections

Replace Thermocouple

Check ALL connections

Low Burner flame

Gas pressure is low

Spider or insect cocoon

Check gas pressures with ma-

nometer.

Check for restricted or plugged

orifice.

Burner Unit


Carbon on reflector & emitter
screen or thick black smoke.


Clean components as needed,
check for probable cause, and
rectify.

Turn the gas valve ON Clean or

replace orifice

Purge air from lines. Open gas

line valve & depress control knob

for approx 2 mins.

Check igniter lead and fittings.

Check and replace if necessary

Purge air from lines

Check set-up and re-position then

retry.

Pilot can be lit manually with a

match or taper. Replace faulty ig-

niter.

9. TROUBLE SHOOTING

This heater must only be serviced by a trained gas service technician. Failure
to comply could result in personal injury, death, fire and/or property damage.

Page 11