Propane – Schwank Parasol Series Post Mount User Manual

Page 6

Advertising
background image

4SN/L5,4BN/L6 Manual

IM080630

RD: JUNE 2008

RL: 1A

BA

PROPANE:

NEVER CONNECT AN UNREGULATED GAS SUPPLY TO THE HEATER.


PRECAUTIONS:

· Periodically check the whole system for leaks or if the smell of gas is detected.
· Extinguish all open flames. Perform ALL leak testing outdoors.
· Never leak test while smoking.
· If you can not stop a leak, turn off the gas supply and call a qualified and licensed techni-

cian, or your gas supplier.

· Only those parts recommended by the Manufacturer should be used. Substitution will void

the warranty.

· Do not use the heater until all connections have been leak tested and are sound !!!


GAS REQUIREMENTS:

· Maximum inlet pressure to propane regulator must not exceed 125 psi.
· A Minimum supply pressure of 11.0” w.c. is required to maintain correct burner input.
· The pressure regulator and hose assembly supplied with the appliance MUST be used.

Any

replacement pressure regulator and hose must conform to standards & specifications of
the Manufacturer and all local codes.
· The installation must conform with local codes, or in the absence of local codes, with Na-

tional Fuel Gas Code.

3.2 Series 4SL5/4BL6 specifications:

· Operating pressure 11” w.c.
· Inlet gas supply pressure

minimum 5 psi / maximum 125 psi

· Maximum operating input rating

38,000 BTUH

· Low fire input rating

22,000 BTUH

· Effective radiant range 8 to 20 foot circle

(affected

by

wind

and

ambient

temperature)

·

Fuel

Propane


· Net Weight

60 lbs


· Certifications CSA International US and Canada

Page 3