Schwank sportSchwank User Manual
Page 11
sportSchwank Manual
IM080731
RD: July 2008
RL: 01A
BA
Page 8
6. DIMENSIONS & CONFIGURATION sportSchwank SERIES
TABLE 2
FIGURE 3: DIMENSIONS
To ‘size’ the transformer required to oper-
ate multiple heaters in one control zone:
First heater in zone requires 40 VA
Each additional heater: plus 20 VA
The sum total will be the required
transformer rating
If total VA exceeds one available
transformer rate (in between sizes) se-
lect the next higher VA rating
Refer to Section 9 - Electrical Require-
ments
sportSchwank
Dimensions
Capacity
Weight
Elect.*
L
In [cm]
S
In [cm]
Btuh [kW]
Lbs [kg]
10
35" [89]
21.7" [55.1]
33,500 [10]
50 [23]
24 VAC
60 Hz
0.55 A
15
50" [127]
32.6" [82.8]
50,000 [15]
71 [32]
20
57" [145]
43.5 [110.5]
67,000 [20]
94 [43]
30
78.7" [200]
65" [165.1]
103,000 [30]
132 [60]
Heater may rotate up to 30° in this direc-
tion. ‘Front’ side must always be located
uppermost when angle mounted. Gas
supply is on the right end when viewed
from front.
END VIEW ALL MODELS
Gas and
electrical
supply this
end.
1/2” MPT