Schwank sportSchwank User Manual

Page 9

Advertising
background image

sportSchwank Manual

IM080731

RD: July 2008

RL: 01A

BA



Provide bracing as required to prevent undue movement of the heater



Seismic bracing, if required, must conform to local codes and engineering prac-
tices



Use Table 2 and Figure 2 to determine the heater dimensions and weight re-
quirements for the design of mounting hardware / brackets

3. The sportSchwank Series heater is approved for both horizontal and angle mount-

ing. When angle mounting, the short axis may be rotated to a maximum of 30°.
For either horizontal or angle mounting on the short axis, the long axis of the heater
must be in a horizontal position.

4. Maintain the minimum clearances to combustibles as indicated in Section 7.

5. Connect heater to the main gas line. When possible, use an approved 1/2" flexible

connector (available as an option from the manufacturer or your local supplier) to
absorb gas line expansion and any vibration - check local code requirements.

6. Leak and pressure test all gas supply lines

7. Set up gas supply pressures at heater to ensure proper manifold pressure (see

Section 2.5 and TABLE 1)

8. Ensure proper electrical rating in the system by checking voltage at ignition module

terminals. (refer to Section 9) To avoid system malfunction, the voltage range must
be within 21.6 Volts to 26.4 Volts, and correct polarity must be maintained through-
out the system.

9. Test-fire the heating system by following the lighting instructions as shown below

and on heater.

4. LIGHTING INSTRUCTIONS

1. Ensure the correct voltage is supplied and gas valve is in the ON position.

2. Turn on power to heater, set thermostat (if applicable) to desired setting, the

heater will light.

3. If heater does not light: Turn off power to heater, turn gas valve to OFF position.

4. Wait for five minutes and repeat steps above. If heater does not light after three

attempts, call a qualified service technician.

5. SHUT DOWN INSTRUCTIONS

1. For temporary shutdown, turn off the electrical supply.

2. For complete shutdown, turn off the electrical supply and turn gas control knob to

the "OFF" position.

Page 6