Minimum, Iep 4024, Heater mounting – Schwank IEP-4024 User Manual

Page 10: Table 2, Required clearances, Figure 2: minimum required clearances

Advertising
background image

10

IM110822

RD: AUGUST 2011

RL; 1A

BA

InfraSave IEP-4024 Manual

TABLE 2:

MINIMUM

REQUIRED CLEARANCES

IEP 4024

Above ‘A’

Inches [cm]

Floor ‘F’

Inches [cm]

Clearance ‘C’

Inches [cm]

4000 W, 230 - 240V, 60 Hz, 18 Amps
(9 Amps each of two branch circuits)

12” [30]

72” [180]

36” [90]

Spacing ‘D’

Inches [cm]

More than

36” [90]

Heater Mounting:

1. Mount the heater on a non-combustible surface or structural member, and maintain at

least all minimum clearances indicated in Table 2 and Figure 2 above.

2. Use the Mounting Brackets supplied with the heater - see Figure 3 next page.

3. Hardware to fasten the Mounting Bracket to the structure is field supplied by the installer

since the type of hardware fastening is determined by site conditions.

4. Each Mounting Bracket fastens to the wall using two (2) field supplied bolts or lag screws

through two holes in one side of the bracket. Mount brackets to the wall with a separation
distance of 35-

5

/

8

inches [90.5 cm] to fit the heater between the mounting extensions of

the brackets - see next page.

5. Fasten the Mounting Brackets ‘plumb’ and aligned level to each other (35-

5

/

8

inches [90.5

cm] between mounts) so that the heater is oriented horizontally on the long axis.

FIGURE 2: MINIMUM Required Clearances

continued ...

FASTEN BRACKETS TO STRUCTURAL MEMBER (OR
EQUIVALENT STRENGTH AND INTEGRITY) OF A NON-
COMBUSTIBLE WALL / SURFACE

LONG AXIS: HORIZONTAL

DO NOT PLACE ANYTHING CLOSER THAN 3 ft (90 cm)
(CLEARANCE ‘C’) IN FRONT OF OR BELOW THE HEATER