Operating instructions 5. electrical connection – Schwank IEP-4024 User Manual

Page 12

Advertising
background image

12

IM110822

RD: AUGUST 2011

RL; 1A

BA

InfraSave IEP-4024 Manual

6. OPERATING INSTRUCTIONS

5. ELECTRICAL CONNECTION

Connect each lamp circuit to a 230 - 240 Vac, 60Hz, 9 Amp copper wire circuit that is prop-
erly grounded. Electrical connection must be performed by a qualified electrical tradesperson.
Installation must conform with the latest edition Electrical Code ANSI/NFPA N0 70 in the
U.S.A. and PART 1 CSA C22.1 in Canada.

1. The heater must be properly installed prior to use.

2. Always ensure the heater is located at a safe distance from the floor, ceiling, side walls,

and combustible materials - refer to Table 2 and Figure 2.

3. Maintain a minimum distance of 36 inches [90 cm] from heater to combustible material.

4. Always be aware and careful of the risk of fire and electric shock.

5. The power cord must not come into contact with hot appliance parts or surfaces and

must not pass in front of the heater.

6. Do not crush the cord, nor drag it over sharp edges, nor place it over a heated hotplate

or open flame.

7. Read, understand, and explain and describe to other users the location, function, and

operation of each control of the heater, including all user-operated devices intended to
reduce the risk of fire, electric shock, or injury to persons and warn against tampering
with such.

8. The heater must only be connected to a 230 - 240Vac, 60 Hz, 9 amp grounded copper

wire circuit outlet. A time delayed fuse may be necessary for circuit protection.

9. If the supply cord is damaged, it must be replaced by a qualified electrician in order to

avoid a hazard.

10. High heat is generated from the front of the heater.

11. Do not allow children to touch or play with the heater.

12. Do not use the heater to dry wet materials or clothing.