Step 4

Remove the 2 Phillips screws that fasten the electrical con-
nection box front face plate in place.



Step 5

Slide the connection box front face plate out from the electri-
cal connection box.



Step 6

Slide power cord retainer plate from electrical connection box
(top surface).



Step 7

Loosen screws in terminal block to remove wires as required:

RED wires connect to Lamp #1 (closer to connection box)
BLUE wires connect to Lamp #2 (further end from box)
Do not disconnect power supply wires
Loosen the threaded clamping collar on the Liquid Tight

Connector located behind the wiring terminal

Pull wires out through the Liquid Tight Connector and top

of electrical connection box

Step 8

Slide lamp wires out of electrical connection box.
Set electrical connection box aside.