Schwank IEP-4024 User Manual

Page 11

Advertising
background image

11

IM110822

RD: AUGUST 2011

RL; 1A

BA

InfraSave IEP-4024 Manual

6.

Ensure that the bolts or lag screws (field supplied) fasten the mounting bracket to the
structure with sufficient strength and integrity to support the weight and prevent move-
ment of the heater. The IEP 4024 weighs 8.8 lbs (4 kg). It is recommended to fasten the
mounting brackets to a structural member (wall studs, etc.) or a field supplied support
that is fastened to structural members.

7.

The heater fastens at each end to the Mounting Brackets using the supplied knob fas-
teners and washers through the outermost hole on the extended leg of the Mounting
Bracket.

8.

Rotate the heater up to 45° on the short axis by loosening the knob fasteners.

9.

Once the heater position is established, hand tighten both knob fasteners firmly to main-
tain the heater in a secure and stable position.

10. Connect each lamp circuit to a 230 - 240 Vac, 60Hz, 9 Amp copper wire circuit that is

properly grounded. Electrical connection must be performed by a qualified electrical
tradesperson. Installation must conform with the latest edition Electrical Code ANSI/
NFPA N0 70 in the U.S.A. and PART 1 CSA C22.1 in Canada.

11. Never allow an electrical cord to pass in front of the heater or to come into contact with

any hot surface of the heater

12. Read and follow all warnings, and the following section on Operation to enjoy safe op-

eration of the heater.

FIGURE 3: MOUNTING BRACKET

FIGURE 4: END VIEW WITH
HEATER BRACKET

Lag Bolt Mounting Brackets to Wall

Align brackets level to each other

35-

5

/

8

inches [90.5 cm] between mounts