Schwank STSp-USA User Manual

Page 13

Advertising
background image

SP-MSTP-AU-05A

STS-p Manual

RD: DEC, 2003

RL: 5

KH

4. Slide the shade end plate hangers and shade plate hangers on the tubes before
assembling the tubes. See Figure 9 for assembled arrangement of the first and
second tubes. For STSp 80, 110, 130, 155, 175 and 200, which will require
additional tubes, an additional coupling and shade end plate hanger will be
required per tube.

NOTE: The first and second tubes on the STSp 60, 80, 110, 130, and 155 are aluminized
and emissive - coated steel respectfully. On STSp 175 and 200, the first section of pipe is
alumatherm, the second is aluminized, and the remaining pipes are emissive - coated steel.

5. Slide the swaged end of the tube into the unswaged end of the adjacent tube.
Center the tube clamps over the joint between the two tubes and tighten the
clamps. See Figure 9.

3. If any of the sections of shade need to be angled, this can be accomplished by
placing the slotted screw in any of the mounting holes situated in a circular pat
tern. Each section of shade can be individually adjusted independent of the
previous or next shades orientation. See Figure 8.

Figure 9

FIGURE 8

Page 9