Schwank 4N/L62-J Pole Mounted User Manual

Page 17

Advertising
background image

GP-M45J-CX-03D

4N/L51-J,4N/L62-J Manual

RD: Aug 2006

RL: 3D

KH

PROBLEM

PROBABLE CAUSE

SOLUTION

Burner will not light

Gas valve may be in OFF position

Turn the gas valve ON

Pilot Orifice blocked

Air in supply system


Loose connection

Electronic Igniter ‘AAA’ 1.5v Battery Dead

1st time ignition

Igniter assembly bent/or not in the correct
position to ignite.

Igniter failure

Clean or replace orifice

Purge air from lines. Open gas line valve
& depress control knob for approx 2 mins.

Check igniter lead and fittings.

Check and replace if necessary

Purge air from lines

Check set-up and re-position then retry.


You can light pilot manually with a match
or taper.

Burner will not stay on

Debris or dirt around the pilot

Loose connections

Clean pilot area

Tighten Connections

Thermocouple faulty

Gas leak in the line

Replace Thermocouple

Check ALL connections

Low Burner flame

Gas pressure is low
Spider or insect cocoon

Check gas pressures with manometer.

Check for restricted or plugged orifice.

Burner Unit

Carbon on reflector & emitter screen or
Thick black smoke.

Clean components as needed, check for
probable cause, and rectify.

9. TROUBLE SHOOTING

WARNING: IMPROPER ADJUSTMENTS, BAD MAINTENANCE OR

SERVICING PROCEDURES CAN CAUSE SEVERE PROPERTY DAMAGE

THIS SECTION IS FOR, CERTIFIED AND LICENSED GAS TECHNICIANS ONLY