KH

PROPANE:

NEVER CONNECT AN UNREGULATED GAS SUPPLY TO THE HEATER.



PRECAUTIONS:

• Periodically check the whole system for leaks or if the smell of gas is detected.

• Extinguish all open flames. Perform ALL leak testing outdoors.

• Never leak test while smoking.

• If you can not stop a leak, turn off the gas supply and call a qualified and licensed technician, or

your gas supplier.

• Only those parts recommended by the Manufacturer should be used. Substitution will void the

warranty.

Do not use the heater until all connections have been leak tested and are sound !!!


GAS REQUIREMENTS:

• Maximum inlet pressure to propane regulator must not exceed 125 psi.

• A Minimum supply pressure of 11.0” w.c. is required to maintain correct burner input.

• The pressure regulator and hose assembly supplied with the appliance MUST be used. Any
replacement pressure regulator and hose must conform to standards & specifications of
the Manufacturer and all local codes.
• The installation must conform with local codes, or in the absence of local codes, with National Fuel

Gas Code.

3.2 Series 4L51/62, 44L5/6 specifications:

• Operating pressure 11” w.c.

• Inlet gas supply pressure minimum 5 psi / maximum 125 psi

• Maximum operating input rating 46,000 BTUH

• Low fire input rating 26,500 BTUH

• Effective radiant range 8 to 20 foot circle
(effected by wind and ambient temperature)
• Fuel Propane

• Net Weight 60 lbs

• Certifications CSA International US and Canada