Installation requirements, Gas supply, General – Schwank 4N/L62-J Pole Mounted User Manual

Page 4

Advertising
background image

GP-M45J-CX-03D

4N/L51-J,4N/L62-J Manual

RD: Aug 2006

RL: 3D

KH

2. INSTALLATION REQUIREMENTS

The Series 4N51/62, 4L51/4L62 and 44N/L5,
44N/L6 Heaters must always maintain the proper
clearance to combustible materials. (Top 18” sides
24” below 24”). Do not use this heater in an explo-
sive atmosphere. Keep heater away from areas
where gasoline or other flammable liquids or va-
pors are stored.

WARNING: Improper operation, installation,
adjustment, alteration, servicing or maintenance
can cause severe property damage, serious injury
or death. Carefully read this User Guide before
installing and setting up the heater.

3. GAS SUPPLY:

The heater comes pre-piped with a flexible hose
assembly inside the pole with 3/8” male flared fit-
ting for hook-up to a 5” w.c. Natural Gas supply.
This heater requires a natural gas pressure regula-
tor (not supplied). Heaters may be connected to a
regulator individually or in zones. Regulators must
be properly sized and adequate for each particular
installation.

These installation and operating instructions are
intended for Series 4N51/62, 4L51/4L62 and

44N/L5, 44N/L6 Heaters. This appliance is an in-
frared fixed pole patio, deck and garden heater for
operation with Natural Gas 4N51, 4N62 and 44N5,
44N6; and Propane 4L51,4L62 and 44L5, 44L6.
The burner is controlled and adjusted by the gas
control knob at the top of the heater, and the gas
supply is fed up through the inside of the pole using
flexible gas hose. All installations must conform to

the following installation requirements, as well as
local and national code requirements, including the
current CAN/CGA-B149.1-00 (latest edition) instal-
lation code and the ANSI Z223.1 (latest edition) for
the U.S.A. for gas burning appliances and equip-
ment. Due to ever changing standards and require-
ments, revision to our equipment and installation
procedures may be necessary. In case of discrep-
ancies, the latest installation manual will take prior-
ity.

Although gas connections on the heater are leak tested at the factory prior to shipment, potential hazards
could result during shipment. Therefore, For Your Safety a complete gas tightness check of all connections
and hoses must be performed at the installation site, prior to use as per code.

TO LEAK TEST:
Make a soapy solution part liquid detergent and one part water. The soap solution can be applied
with a spray bottle, brush or rag. Soap bubbles will appear where a gas leak is present.

1. GENERAL

Page 1

NATURAL GAS

PROPANE

The heater comes equipped with a hose assembly
for hook-up to a propane gas supply.

Never use a propane supply with a

damaged valve connection.

Never connect an unregulated propane

supply to the heater

Advertising
This manual is related to the following products: