Installation – Regency Horizon HZ54E Large Gas Fireplace User Manual

Page 23

Advertising
background image

Regency Horizon HZ54E-1 Gas Fireplace

23

INSTALLATION

H

H1

V

V1

H1

H

V

Horizontal Venting with Two (2) 90

o

Elbows

NG and LP

Horizontal Venting with Three (3) 90

o

Elbows

NG and LP

One 90

o

elbow = Two 45

o

elbows.

Option V

H V + V1 H + H1

A)

2' Min. 1' Max. 3' Min. 2' Max.

B)

2' Min. 2' Max. 5' Min. 4' Max.

C)

3' Min. 2' Max. 7' Min. 5' Max.

D)

4' Min. 3 Max. 9' Min. 6' Max.

E)

5' Min. 4' Max. 10' Min. 7' Max.

F)

6' Min. 6' Max. 11' Min. 9' Max.

With these options, max.
total pipe length is 30 feet
with min. of 11 feet total
vertical and max. 9 feet total
horizontal.

Please note min. 1 foot
between 90

o

elbows is

required.

VENT RESTRICTOR SETTING:
Vent restrictor factory set at Set 1, no adjustment required.

One 90

o

elbow = Two 45

o

elbows.

Option

V

H + H1

With these options,
maximum total pipe
length is 30 feet with
minimum of 6 feet total
vertical and maximum
10 feet total horizontal.

A)

2' Min.

4' Max.

B)

3' Min.

6' Max.

C)

4' Min.

8' Max.

D)

5' Min.

9' Max.

E)

6' Min.

10' Max.

Please note minimum 1 foot between 90

o

elbows is

required.

VENT RESTRICTOR SETTING:
Vent restrictor factory set at Set 1, no adjustment
required.

Advertising