Installation, Wall switch, Optional wall thermostat – Regency Horizon HZ54E Large Gas Fireplace User Manual

Page 36: Optional remote control

Advertising
background image

36

Regency Horizon HZ54E-1 Gas Fireplace

INSTALLATION

WALL SWITCH

(Included with Unit)

1) Run the supplied 10' of wire through the right

or left side gas inlet opening. Be careful not to
damage wire.

Note: We recommend a maximum of 10' of wire

but if you wish to go with a longer run,
use the Thermostat Wire Table.

2) Connect the wire to the wall switch and install

into the receptacle box (supplied). Also attach
wires to the valve as shown below.

CAUTION

Do not wire millivolt

wall switch wire

to 120V wire.

Optional

WALL THERMOSTAT

A wall thermostat may be installed if desired,
connect the wires as per the wiring diagram. Use
table below to determine the maximum wire length.

Note: Preferable if the thermostat is installed

on an interior wall.

Regency

®

offers an optional programmable

thermostat but any 250-750 millivolt rated non-
anticipator type thermostat that is CSA, ULC or
UL approved may be used.

CAUTION

Do not wire millivolt

wall thermostat wires

to 120V wire.

Thermostat Wire Table

Optional

REMOTE CONTROL

Use the Regency

®

Remote Control Kit approved

for this unit. Use of other systems may void your
warranty.

The remote control kit comes with a hand held
transmitter, a receiver and a wall mounting plate.

1) Choose a convenient location on the wall to

install the receiver and the receptacle box
(protection from extreme heat is very important).
Run wires from the fi replace to that location.
Use Thermostat Wire Table.

CAUTION

Do not wire millivolt

remote control wires

to 120V wire.

2) Connect the two wires to the IPI wire harness

.See wiring diagrams. Optional wall switch GT/
GTM suing wire 0.584.907.

3) Install 3 AAA alkaline batteries in the transmit-

ter and 4 AA alkaline batteries in the receiver.
Install the receiver and it's cover in the wall.
Switch the remote receiver to "remote" mode.
The remote control is ow ready for operation.

14 GA.
16 GA.
18 GA.
20 GA.
22 GA.

50 Ft.
32 Ft.
20 Ft.
12 Ft.

9 Ft.

Recommended Maximum Lead Length

(Two-Wire) When Using Wall

Thermostat (CP-2 System)

Wire Size Max. Length

Advertising