Usg drywall suspension system, Drywall suspension system, Dglw26 – USG Exterior Ceiling Applications Systems Guide User Manual
Page 32: Technical data
Advertising
31 USG Exterior Ceiling Applications
USG
™
Drywall Suspension System
DGLW26
Technical Data
Spacing
Uplift Class
Test
Standard
Test
Record
Maximum
Load Rating
(w)
Equivalent
Wind Speed
(v)
Main Tee
Cross Tee
Compression
Post
DGLW26
48 in
24 in
24 in
Class 15
UL580
UL526
15 psf
77 mph
48 in
16 in
30 in
Class 15
UL580
UL526A
15 psf
77 mph
48 in
24 in
30 in
Class 15
UL580
UL526B
15 psf
77 mph
24 in
24 in
30 in
Class 30
UL580
UL526C
30 psf
108 mph
24 in
24 in
42 in
Class 60
UL580
UL526D
30 psf
108 mph
24 in
24 in
30 in
Class 90
UL580
UL526E
90 psf
188 mph
24 in
16 in
24 in
Class 90
UL580
UL526F
90 psf
188 mph
24 in
16 in
24 in
N/A
Miami Dade
TAS202&203
NOA
12-0924.03
75 psf
171 mph