9
Output Connection Options
Mating Connector Kits
PlugMate Pin Out
(Looking into PlugMate)
Vicor P/N 25073
Vicor P/N 25067
Vicor P/N 25061
PlugMate
(Factory Installed Option)
Micro PlugMate
Mini PlugMate
Maxi PlugMate
Pin #
Function
Pin #
Function
1
+Vout
5
+Vout
2
+Vout
6
N/C
3
–Vout
7
SC
4
–Vout
8
–Vout
Pin #
Function
Pin #
Function
1
+Vout
10
+Vout
2
+Vout
11
+Vout
3
+Vout
12
+Vout
4
N/C
13
+S
5
N/C
14
SC
6
N/C
15
–S
7
–Vout
16
–Vout
8
–Vout
17
–Vout
9
–Vout
18
–Vout
Pin #
Function
Pin #
Function
1
+Vout
13
+Vout
2
+Vout
14
+Vout
3
+Vout
15
+Vout
4
+Vout
16
+Vout
5
+Vout
17
+Vout
6
N/C
18
+S
7
SC
19
–S
8
–Vout
20
–Vout
9
–Vout
21
–Vout
10
–Vout
22
–Vout
11
–Vout
23
–Vout
12
–Vout
24
–Vout
1
4
5
8
1
9
10
18
1
12
13
24
Mating Conn.
Amp. P/N Vicor P/N
Housing
TYC-794657-8
25056
Pin
1-106529-2
24796
Kit
25073
Mating Conn.
Amp. P/N Vicor P/N
Housing
TYC1-794657-8 25050
Pin
1-106529-2
24796
Kit
25067
Mating Conn.
Amp. P/N Vicor P/N
Housing
TYC2-794657-4 25044
Pin
1-106529-2
24796
Kit
25061
Please Note:
VIPACs that contain multiple modules configured as a single output (paralleled for power
or redundancy) MUST have their Outputs and Sense connected to each other at the load.
DO NOT OPERATE A PARALLEL CONFIGURATION WITH ONLY ONE MODULE CONNECTED.