The full-chip PRM-RS Customer Board described in this document is designed for use with the
Remote Sense (RS) family of full-chip PRM

®

regulators, and demonstrates the benefits of

Factorized Power Architecture™. This demonstration board is not designed for installation in end-
user equipment. The system demonstrates the use of a PRM Regulator and a VTM

®

Current

Multiplier for general laboratory evaluation only.

Please read this document before setting up a customer demonstration board.

The User Guide is not comprehensive and is not a substitute for common sense and good

practice. For example:

1. When testing electronic products always use approved safety glasses.

2. Provide a strain relief for wires and place the system on the bench in such a way as to prevent

accidental dislodgment from the bench top.

3. Remove power and use caution when connecting and disconnecting test probes and interface

lines to avoid inadvertent short circuits and contact with hot surfaces.

4. Never use a jumper in place of the fuse. Replace the fuse only with its equivalent type

and rating.

5. Never attempt to disconnect the demonstration board from a VTM Customer Board while

power is applied. This system is not designed to demonstrate hot plug capability.

1.0 Introduction

The full-chip PRM-RS Customer Board can be used to demonstrate a stand-alone regulator or in

conjunction with a VTM Customer Board to enable demonstration of a Factorized Power

Architecture (FPA) system. There are many combinations possible using PRM and VTM Customer

Boards, but the focus in this user guide is using one PRM Customer Board and one VTM

Customer Board. The full-chip PRM Customer Board can be configured for local sensing (at the

PRM output), or non-isolated remote sensing (at the VTM module output). The full-chip PRM

Customer Board is nominally configured for local sensing where the voltage feedback circuit

regulates the output voltage of the PRM module. Implementing remote sensing requires

component changes and rework to the board which is detailed in section 8.3.

1.1 Part Numbers and Ratings

Refer to the specific PRM module data sheet for ratings of the device. It is important to remain

within the device limits when testing.

1.2 Contents

The full-chip PRM-RS Customer Board arrives with the following contents:

1. 1 x full-chip PRM-RS Customer Board fully populated

2. 1 x 11mm VI Chip

®

push pin heat sink

3. 2 x VI Chip push pins for heat sink installation

4. 2 x VI Chip push pin heat sink grounding clip

5. 2 x 10 pin male to male headers

Full-chip PRM

®

-RS Customer Board User Guide

Contents

Page

Introduction

1

Features

2

General

2 – 4

Schematic

5

Bill of Material

7

VTM Customer
Boards

8

Testing

10

Modifications

16

Conclusions

19

USER GUIDE | UG:009

For use with PCB part number: 35306