Evaluation Board Basic Specifications and Operating Limits
Please use the following table for operating limits:
Note: VI Brick AC Front End Module operating temperature will depend on its Product Grade as
specified in the datasheet.
Please refer to Figure 1 for locations of the input and output connections as viewed
from the component side. Wires may be soldered directly to the pads instead of ring
lugs if desired to minimize circuit impedances.
Figure 1
VI Brick
® AC Front End
Evaluation Board layout and
dimensional drawing,
component side.
Table 1
Operating Limits
Description
Specification Notes
Input Range
85 – 264 Vac
Universal input
Output voltage
48 Vdc
Partially Regulated, SELV
Output Power
330 W
Over entire input range
Operating temperature
-40 to 85°C
Limited by hold-up capacitor
and Z01
Output capacitance
6,000 to 12,000μF
63V rating