Ac input module (aim / mi-aim) – Vicor VI-J00 Family DC-DC Converters and Configurable Power Supplies User Manual

Page 36

Advertising
background image

Design Guide & Applications Manual

For VI-200 and VI-J00 Family DC-DC Converters and Configurable Power Supplies

VI-200 and VI-J00 Family Design Guide

Rev 3.5

vicorpower.com

Page 35 of 98

Apps. Eng. 800 927.9474

800 735.6200

CHOOSING APPROPRIATE VALUES FOR AIM MODULES

Sample calculation:

Converter output power (P

OM

) = 100 W

Line frequency = 60 Hz

Line range = 105 – 264 Vac

Efficiency = 82%

Desired hold-up time = 5 ms (minimum)

therefore:

P

IM

=

100 = 122 W

0.82

T5 – T3 = 5 ms + 8.3 ms = 13.3 ms
(minimum hold-up time plus half cycle)

Vp = 105 X 2 = 148 V

Vdo = 100 V

and:

C1 =

2 X 122 X 0.0133

148

2

– 100

2

C1 = 270 µF

where:

V

P

= The peak of the rectified AC line or 2 X Vac

in

.

For an input range of 85 – 264 Vac, this voltage
will vary from 120 – 373 V.

V

V

= The low point of the rectified AC line under

normal operating conditions. This “valley” voltage
is a function of C1, P

IM

and line frequency. The

peak-to-peak ripple across C1 is V

P

– V

V

and

determines the ripple current in C1.

NOTE: It is important to verify the rms ripple
current in C1 with a current probe.

V

do

= Voltage at which the DC-DC converter(s) begin(s) to

drop out of regulation. This voltage is from the data
sheet of the appropriate module, which for the
VI-270 Family is 100 Vdc. Under normal operating
conditions, V

V

must exceed V

do

.

T1 = The peak of the rectified AC line or the point at

which C1 is fully charged. For an input range of
85 – 264 Vac, this voltage will vary from 120 – 373 V.

T2 = The low point of the rectified AC line under

normal operating conditions and the point at
which C1 is about to be “recharged”. This is the
point of lowest energy in C1.

T4 = The low point of the rectified AC line; the point

of lowest energy in C1; the point at which if the
AC line fails, hold-up time is shortest, i.e., “worst
case”.

T5 = The time at which the converter(s) drop out of

regulation.

T5 – T4 = Minimum hold-up time. Actual hold-up time

may vary up to a maximum of T5 – T3.

(T3 – T1) X 2 = One line cycle.

The following values are calculated in a similar manner.

C1 values as a function of line voltage, frequency and
delivered power, for use with the “7” input designator
DC-DC converters (AIM input of 90–264 Vac) or “5” input
designator (AIM input of 90–132 Vac) DC-DC converters.

NOTE: With “7” input DC-DC converters operated
from the AIM input range of 90 – 264 Vac, 400 V
capacitors must be used (Vicor Part #30240). With
“5” input DC-DC converters used over the AIM input
range of 90 – 132 Vac, 200 V capacitors may be used
(Vicor Part #30769).

C1 values as a function of line voltage, frequency and
delivered power, for use with the “6” input designator
DC-DC converters (AIM input of 180 – 264 Vac).

NOTE: With “6” input DC-DC converters operated
from the AIM input range of 180 – 264 Vac,
400 V capacitors must be used (Vicor Part #30240).

50 W

270 µF

135 µF

300 µF

150 µF

75 W

400 µF

200 µF

440 µF

230 µF

100 W

525 µF

270 µF

600 µF

300 µF

150 W

800 µF

400 µF

890 µF

455 µF

200 W

1,000 µF

540 µF

1,180 µF

600 µF

Table 12–1 — Hold-up capacitor values for use with VI-270 / VI-J70
and the VI-250 / VI-J50 DC-DC converters.

Module(s)

60 Hz

50 Hz

Delivered Power

90 Vac

105 Vac

90 Vac

105 Vac

Table 12–1 — Hold-up capacitor values for use with VI-260 / VI-J60
DC-DC converters.

12. AC Input Module (AIM / MI-AIM)

50 W

66 µF

34 µF

74 µF

38 µF

75 W

100 µF

50 µF

110 µF

60 µF

100 W

130 µF

67 µF

150 µF

75 µF

150 W

200 µF

100 µF

220 µF

115 µF

200 W

262 µF

135 µF

300 µF

150 µF

Module(s)

60 Hz

50 Hz

Delivered Power

180 Vac

210 Vac

180 Vac

210 Vac