Test Procedure:

Initial Test Set Up

PI2007-EVAL2 is designed with two bias circuit
options, bias via 1% external resistor (R3 and R4) or via
internal resistor (VR input). R3 and R4 resistors are
installed (430Ω, 1%).

Baseline Test Procedure – PI2007 (Refer to Figure 3)

1. Recommended Material

1.1. Material Needed-Picor supplied

1.1.1. PI2007-EVAL2
1.1.2.

PI2007 Product Datasheet

1.2. Recommended Users Supplied Equipment

1.2.1. Two DC power supplies: 0-20V; 20A each.
1.2.2. One low power logic voltage power supply
1.2.3. Load: electronic Load, Power resistors or

actual load.

1.2.4. Multimeter.
1.2.5. Oscilloscope.
1.2.6. Appropriately sized interconnect cables.
1.2.7. Safety glasses.




Figure 3: