Vicor VI Chip VTM Evaluation Board User Manual

Page 6

Advertising
background image

UG:014

vicorpower.com

Applications Engineering: 800 927.9474

Page 6

Reference

Designator

Functional

Name

Functional
Name

H15,

H14

+S,

–S

Sockets for +S and –S test points.

TP18,

TP19

AC SIG INJ

Can be used to inject the isolated signal of network analyzer for bode
plot measurement to measure the stability in Remote Sense operation
using VTM and PRM

H18,

H19

AC SIG INJ

Sockets for AC +/- test points.

TP30

IM

IM test point provides the kelvin connection to IM pin. Can be used to
measure the IM signal of the half VTM. IM can be used to monitor the
output current of the VTM. Available on half VTM boards only.

H27

IM

Socket for IM test point.

Test Points and Sockets Description (Cont.)

Advertising