Operating manual Light Control „PULSE PIR - Vers. IV“
ENG
Function 2.7
Special function
The special function is not avai-
lable.
The function cannot be changed.
Explanation of the functions (part 6)
Function 4.1 - 4.6
Presence range
Function to set the detection range
of the presence sensor.
The default setting for the range of
the presence sensor is 100%.
The function cannot be changed.
Function 3.1 - 3.6
Follow-up time
Function to adjust the time after
which the light is to be switched off
if no presence is detected.
The default setting of the follow-up
time is 10 min.
6 different follow-up times from
5 to 30 min can be set.
The function can be changed on
lights with sensors XXX /R
Fig. 2
LED II
Key II
LED I
Key I
Sensor
Note: The functions written
in
blue
are not available.